CHR0013: Reactor cannot combine EventStore with explicit event sequence
Rule Description
A reactor that declares [EventStore("...")] must use implicit inbox routing. It cannot also define an explicit event sequence.
Severity
Error
Example
Violation
using Cratis.Chronicle.Events;
using Cratis.Chronicle.Reactors;
[EventStore("identity-service")]
[Reactor(eventSequence: "custom-sequence")]
public class UserSyncReactor : IReactor
{
}
Fix
using Cratis.Chronicle.Events;
using Cratis.Chronicle.Reactors;
[EventStore("identity-service")]
[Reactor]
public class UserSyncReactor : IReactor
{
}
Why This Rule Exists
[EventStore] on a reactor is intended to drive outbox-to-inbox routing. Combining it with explicit event sequence configuration creates ambiguous routing intent.
Related Rules
- CHR0014: Reducer cannot combine EventStore with explicit event sequence